This is an an
architectural aluminium secondary glazing system anchored into a
hardwood subframe for maximum sound insulation and should not be
confused with upvc or aluminium diy kits, it is fitted in St Paul's
Cathedral and Teesside airport to name a tiny few of the architectural
projects that this system has been used.
Secondary Glazing UK
Test
for Watertightness
Test in accordance with
BS6375. Part 1: Water temperature 17ºc classified for watertightness.
Test pressure class (Pa): 300
Occurrence
of Leakage
Position
of Leakage
Pressure
(Pa)
Time
(min)
400
41
Leakage
through fixed joint at X
500
47
Upwards
spray at Y
600
50
Leakage
through beading applied to cill at Z
Limit
of Watertightness (Pa)
300Pa
Air
Permeability
Test in accordance with
BS5368 Part 1: Air temperature 19.5ºc, total window area 2.01m², this
window is classified for air permeability as follows:
Test Pressure class
(Pa):600
Acoustic
Performance
Sound Reduction Index measurements were
conducted at the AIRO Acoustics Laboratory in accordance with BS2750: Part
3: 1980 and BS5821: Part 3: 1984, using a purpose built transmission
suite. AIRO is accredited as a NAMAS TESTING Laboratory NO.0483.
The weighted sound reduction index, Rw =
45dB (BS5821: Part 3: 1984)